M01 - Spinning Disk Confocal UltraView VoX AxioObserver (inverted)
M02 - Axio Imager.Z2 (upright) with sCMOS camera
M03 - Axioplan2  - Histo
M05 - Axio Imager.Z2 (upright) with sCMOS camera
M06 - Axioobserver Z1 (inverted) mit sCMOS camera
M07 - Axio Imager.Z2 (upright) with sCMOS camera
M09 - LSM780 Axio Observer (inverted) with incubation
M11 - VertA1 with Fluorescence - for cell culture dishes
M12 - Leica Stereomicroscope with fluorescence
M16 - Axioobserver Z1 (inverted) with sCMOS camera and incubation
M17 - Fluorescence Stereomicrocope Lumar with HBO lamp
M19 - Pannoramic SCAN 150
M20 - TIRF 3 System Axio Observer (inverted) with incubation
M21 - LSM 710 2Pi Axio Observer (inverted) with incubation
M22 - LSM700 Axio Imager (upright)
M23 - LSM700 Axio Imager (upright)
M24 - LSM780 Axio Imager (upright)
M25 - Spinning Disk Confocal UltraView Vox Axio Observer (inverted) with incubation
M26 - LSM780 Axio Observer (inverted) with incubation
M27 - LSM880 Axio Observer (inverted) with Airyscan/Airyscan fast and incubationM26 - LSM780 Axio Observer (inverted) with incubation
M28 - Pannoramic FLASH 250 II
M29 - Pannoramic SCAN 150
M30 - Pannoramic FLASH 250 III
M31 - Visiscope Spinning Disk Confocal with Incubation and FRAP unit
M32 – Zeiss Z1 Lightsheet Microscope
M33 - LSM880 Axio Observer (inverted) with Airyscan/Airyscan fast and incubation and 40x/1.2W, Glycerol AutoCorr objective

Leica Laser Microdissection System

OMX Structured Illumination Microscope
FLIM - Picoquant Fluorescent Lifetime Imaging Microscope

Microscopy techniques

Microscopy techniquesSystem number

Widefield



Confocal



2Pi

TIRF

Slide Scanner


Laser Microdissection

fluorescence and
nonfluorescence

Spinning Disk
Point Scanner
Line Scanner





fluorescence and nonfluorescence

M01M02M03M05M06M07M11M12, M13, M16M17M19M29, M28

M01M25
M09M21M22M23M24, M26, M27
M18

M21


M20

M19, M29, M28, M30


UNI

Applications

ApplicationsSystem number

Fixed sample imaging


Live Cell Experiments



Multipoint experiment (timelapse on different positions on the same slide)

Multislide experiment (timelapse on different positions on different slides - up to 4 or 8 slides)

F-techniques (FRAP, FLIP, FRET)

Automated acquisition of a high number of images from one or more slides to obtain statistically relevant results

High throughput imaging

Screening

Lasermicrodissection of various live and fixed samples (tissue, cells) for further cultivation and analysis




confocal
widefield   


confocal - temp, CO2, moisture control
widefield - temp, CO2, moisture control


widefield
confocal



widefield
confocal




confocal


widefield
confocal


M01M09M21M22M23M24M25, M26, M27
M01M02M03M05M07M11M12, M13, M16M17M19, M27, M28 

M01
, M09M21M22M23M24, M25, M26, M27

M13, M16, M20, OMX


M13, M06, M16
M01M09M21M22M23M24M25, M26, M27



M06, M16
M01M09M21M22M23M25, M26, M27




M09M21M22M23M24, M26, M27


M06, M13, M16M19, M29, M28
M01M09M21M22M23M24M25, M26, M27




M19, M22, M23M29, M28


M19M28M29M22, M23

UNI